Avaya
(Redirected from Avaya 4620SW)
1608
Power (over Ethernet) compatibility:
barrel plug: 5.5/2.5 5V
straight | crosslink | |
---|---|---|
802.3af | yes | unknown |
legacy | unknown | unknown |
compatible | unknown | unknown |
Unifi | unknown | unknown |
Note:
- H.323 only
- default password 27238 (craft)
4620SW
- only uses pins 1,2,3 + 6 (100Base-T)
- PoE compatible
- custom power module available: GND:pin 7, +48V:pin 8
- upon booting (about 20 seconds), the following message appears:
- 100 mbps ethernet (you might want to unplug the ethernet cable if the keys do not respond)
- * to program (after this step, you can plug in the ethernet connection again so you are able to type in the SIG command at the end)
- press *
- confirm every default with # (8x)
- at the end, it says "No new values. #=OK": confirm
- at the blank screen, type mute744# (Mute SIG#, you will notice a distinct short tick when pressing mute, and other keys being silent)
- change to SIP by cycling using * and confirm using #
- default password 27238 (craft)
You will need a TFTP server and the 46xxSettings.txt file (see Avaya's sample and a snippet from LeftyBC on github gist
Power (over Ethernet) compatibility:
barrel plug: none
straight | crosslink | |
---|---|---|
802.3af | yes | yes |
legacy | no | no |
compatible | yes | yes |
Unifi | unknown | unknown |
Note:
9608
9611
Power (over Ethernet) compatibility:
barrel plug: none
straight | crosslink | |
---|---|---|
802.3af | yes | unknown |
legacy | unknown | unknown |
compatible | unknown | unknown |
Unifi | unknown | unknown |
Note:
- default password 27238 (craft)
9650
- default password 27238 (craft)
- latest supported SIP firmware version seems to be 2.6.17.0
- also uses 46xxsettings.txt
$MACADDR
is not usable in the config fileSKINS
andCURRENT_SKIN
doesn't workCURRENT_CONTENT
works: even the option of adding hidden menusCURRENT_LOGO
doesn't workSET SIP_CONTROLLER_LIST
is most likely numeric- no support for
FORCE_SIP_*
- 8+1 auxiliary buttons are not programmable, only the 3 appLines, 4 softKeys and 5 hardButtons (calllog, contacts amenu, message, forward)
- doesn't handle
401 Unauthorized
- xopr had problems with ACK/BYE from the phone (it never hangs up and some calls will disconnect after ~30 seconds)
Power (over Ethernet) compatibility:
barrel plug: none
straight | crosslink | |
---|---|---|
802.3af | yes | yes |
legacy | no | no |
compatible | yes | yes |
Unifi | unknown | unknown |
Note: Location: xopr's (project crate and a bunch at home)
B189
Power (over Ethernet) compatibility:
barrel plug: none
straight | crosslink | |
---|---|---|
802.3af | yes | unknown |
legacy | unknown | unknown |
compatible | unknown | unknown |
Unifi | unknown | unknown |
Note: Features:
- default password 27238 (craft)
- H.323 only
- color touchscreen
- Gigabit ethernet (single port)
- Has mini USB: it doesn't power the device, it doesn't enumerate on the PC correctly and is marked "for future use" in the manual. Also booting with several button combinations didn't triger a valid USB port