Difference between revisions of "Siemens Gigaset"

From Hackerspace ACKspace
Jump to: navigation, search
(added Targa DIP phone 450 (Gigaset "clone") device. Cleanup small bobs)
m (typo's and layout)
Line 128: Line 128:
 
* every handset needs to be registered to every basestation, so 24 registrations maximum
 
* every handset needs to be registered to every basestation, so 24 registrations maximum
 
* I had some success using an old Profoon PDX-2900:
 
* I had some success using an old Profoon PDX-2900:
  * have base station registration activated before entering the PIN
+
** have base station registration activated before entering the PIN
  * press and hold ➡️\📞👤 for 3 seconds (🔋 and 🛜 (or 📞👤) will blink)
+
** press and hold ➡️\📞👤 for 3 seconds (🔋 and 🛜 (or 📞👤) will blink)
  * press and hold *️⃣🔕 for 3 seconds (it will prompt: <code>bS-_</code>
+
** press and hold *️⃣🔕 for 3 seconds (it will prompt: <code>bS-_</code>
  * choose <code>1</code> to <code>4</code> (it will prompt: <code>bS-4 PIN_</code>
+
** choose <code>1</code> to <code>4</code> (it will prompt: <code>bS-4 PIN_</code>
  * enter the base station's PIN code
+
** enter the base station's PIN code and finish with 📞
  
  
 
[[Category:Telephony]][[Category:PoE]]
 
[[Category:Telephony]][[Category:PoE]]

Revision as of 20:43, 3 January 2025

general info

N510 IP PRO

  • manual
  • Runs on 6.5V (1.2-1.3W)
  • supports 6 GAP handsets
  • 6 handsets
  • up to 4 simultaneous calls
  • Supports IEEE802.3af (PoE)
  • Info Center support (TBD)


Power (over Ethernet) compatibility:
barrel plug: unknown 6.5V

straight crosslink
802.3af yes yes
legacy no no
compatible yes yes
Unifi no no

Note:

The device supports two distinctive rings; default (extenal) and alert-internal:

Alert-Info: <http://www.notused.com>;info=alert-internal

Exposed internals:

connecting the N510 IP PRO

Under Settings » Telephony » Connection, the following settings are needed:

  • Connection name or number: <anything>
  • Provider: Other provider
  • Authentication name: <username>
  • Authentication password: <password>
  • Username: <username>
  • Display name: <anything>
  • Lookup Enabled (if available, version ≥ 240): yes
  • Domain: ackspace.nl
  • Proxy server address: <leave empty>
  • Proxy server port: <leave empty to trigger SRV lookup>
  • Registration server: <leave empty>
  • Registration server port: <leave empty to trigger SRV lookup>
  • Registration refresh time: 110
  • STUN enabled: Yes
  • STUN server address: stun.ekiga.net
  • STUN server port: 3478
  • STUN refresh time: 240
  • Outbound proxy mode: Automatic
  • Outbound proxy port: <leave empty to trigger SRV lookup>
  • Select network protocol: Automatic
Note that these settings take a while for the Gigaset to connect to the right server (it might indicate an error at first).
Also, make sure that under Settings » Telephony » Advanced VoIP settings, SIP port: (or its random range) does not conflict with other SIP devices behind the same NAT.


Targa DIP phone 450

  • manual
  • Runs on 6.5V (1.2-1.3W)
  • supports 6 GAP handsets
  • 6 handsets
  • 1 simultaneous call


Power (over Ethernet) compatibility:
barrel plug: unknown 6.5V

straight crosslink
802.3af no no
legacy no no
compatible no no
Unifi no no

Note:

connecting the Targa DIP phone 450

SRV does not seem to work, and the port fields are not emptied.

Under Settings » Telephony » VoIP, the following settings are needed:

  • Connection name or number: <anything>
  • Provider: Other provider
  • Authentication name: <username>
  • Authentication password: <password>
  • Confirm authentication password: <password>
  • Username: <username>
  • Display name: <anything>
  • Lookup Enabled (if available, version ≥ 240): yes
  • Domain: ackspace.nl
  • Proxy server address: sip.ackspace.nl
  • Proxy server port: 5060
  • Registrar server: sip.ackspace.nl
  • Registrar server port: 5060
  • Registration refresh time: 110
  • STUN enabled: Yes
  • STUN server address: stun.ekiga.net
  • STUN server port: 3478
  • STUN refresh time: 240
  • Outbound proxy mode: Automatic
  • Outbound proxy: sip.ackspace.nl
  • Outbound proxy port: 5060
  • Select network protocol: Automatic
Note that these settings might take a while for the TARGA to connect to the right server (it might indicate an error at first).
Also, make sure that under Settings » Telephony » Advanced VoIP settings, SIP port: (or its random range) does not conflict with other SIP devices behind the same NAT.

notes

xopr had a look at the (poor man's) roaming option that is available. In short:

  • you need a "pro" handset that allows multiple base stations (4 is mentioned); when registering to a base station, this option automatically passes by
  • every handset needs to be registered to every basestation, so 24 registrations maximum
  • I had some success using an old Profoon PDX-2900:
    • have base station registration activated before entering the PIN
    • press and hold ➡️\📞👤 for 3 seconds (🔋 and 🛜 (or 📞👤) will blink)
    • press and hold *️⃣🔕 for 3 seconds (it will prompt: bS-_
    • choose 1 to 4 (it will prompt: bS-4 PIN_
    • enter the base station's PIN code and finish with 📞